katse/test, mis viiakse läbi alljärgnevatel tingimustel: tööolukorras arvesti, pingeahelad ja abiahelad pingestatud nimipingega ±5 %, vooluahelad vooluta, kontaktlahendus, katsepinge 8 kV, lahenduste arv 10, kusjuures katse ei ole rakendatav elektromehaanilistele arvestitele, test that be carried out under the following conditions: tested as table-top equipment, meter in operating condition, voltage and auxiliary circuits energized with reference voltage ±5 %, without any current in the current circuits, contact discharge test voltage 8 kV, number of discharges 10, and this test is not applicable to electromagnetical meters